YEASEN은 생명과학 연구 및 진단을 위한 고품질의 연구용 시약과 기기를 제공하는 글로벌 바이오 기업입니다.

제품 설명
Hieff NGS™ MaxUp Human/Mouse/Rat rRNA Depletion Kit(rRNA ITS/ETS) 2.0
제품 번호
12726ES
제품 설명
Hieff NGSTM MaxUp Human/Mouse/Rat rRNA Depletion Kit (rRNA & ITS/ETS) 2.0 utilizes an RNase H digestion method to remove ribosomal RNA (rRNA) and the 45S & ITS/ETS regions from total RNA isolated from human, mouse, and rat samples, thereby enriching messenger RNA (mRNA) and other non-coding RNAs. This kit effectively removes rRNA from both intact and partially degraded total RNA (such as FFPE-derived RNA). Since degraded FFPE samples typically contain a higher proportion of ITS/ETS fragments compared to fresh tissue samples, the inclusion of specific probes targeting the human, mouse, and rat 45S & ITS/ETS regions in this kit significantly increases the proportion of usable sequencing data after depletion.
Features
Components No. | Name | 12726ES12 | 12726ES24 | 12726ES96 |
12726-A | Hybridization Buffer | 36 μL | 72 μL | 288 μL |
12726-B | Human Probe Mix (rRNA & ITS/ETS) | 24 μL | 48 μL | 192 μL |
2726-C | RNase H Buffer | 36 μL | 72 μL | 288 μL |
12726-D | Thermostable RNase H | 4 μL | 48 μL | 192 μL |
2726-E | DNase I Buffer | 330 μL | 660 μL | 2x1320 μL |
12726-F | DNase l | 30 μL | 60 μL | 240 μL |
This product should be stored at -25~-15℃ for 12 months.
1. Broad Compatibility Across Input Amounts and Sample Types

Figure 1. Efficient rRNA Removal Across Multiple Sample Types and Input Amounts
Library preparation was performed using 12726 and RNA Library Preparation Kit (Cat#12308, with strand-specific protocols) on various RNA sample types—including human, mouse, and rat total RNA—across different input amounts (100 ng to 1 μg). The rRNA residual rate remained consistently low and was significantly reduced compared to Supplier V* across all sample types and input levels.
2. Effective rRNA Removal

Figure 2. Comparison of rRNA Removal Efficiency by Sequencing and qPCR
Using 1 μg of 293T total RNA, samples were processed by oligo-dT enrichment or rRNA depletion. Sequencing measured residual rRNA%(A). qPCR targeting cytoplasmic (18S, 28S, 5.8S) and mitochondrial (12S, 16S) rRNAs showed significant Ct value increases after depletion(B), demonstrating effective rRNA removal.
3. Stability

Figure 3. Stability Test
(A) 1 μg RNA standard was used to compare rRNA removal efficiency between Yeasen (Cat#12726ES) and Supplier V* after storage at 4 °C for 3 days or freshly prepared. Yeasen’s kit maintained normal removal efficiency and outperformed the competitor. rRNA levels were assessed by qPCR targeting 18S, 28S, and ACT.
(B) RNA standard (547 ng/μL) was fragmented (94 °C, 7 min) and RNA Libraries were prepared using Yeasen Kit (Cat#12308, with strand-specific protocols). rRNA removal remained stable after 11 days at 4 °C, comparable to freshly prepared reagents.
YEASEN의 모든 제품을 만나 보세요!