본문 바로가기 주메뉴 바로가기

제품소개

제품상세페이지

Celnovte

[Celnovte] Ki-67(C3G4), MMab

Cat-No. CKM-0032


Celnovte는 병리학적 진단 시약과 기기를 연구, 개발, 제조 및 유통하는 바이오기업입니다. 




제품 설명


Ki-67(C3G4), MMab




제품 번호


CKM-0032

 



제품 특징


Ki67 is a cell proliferation marker that is closely related to the cell cycle. There is expression in G1, S, G2, M period,there is no expression in G0 period. Its proliferation index is closely related to the degree of separation, leaching metastasis and prognosis of many tumors.


Photo Staining Tissue

The Ki67 antigen is a nuclear protein which is expressed in all active parts of the cell cycle (G1, S, G2 and mitosis) but is absent in resting cells (G0). In contrast to many other cell cycle-associated proteins, the Ki67 antigen is consistently absent in quiescent cells and is not detectable during DNA repair processes. Thus, the presence of Ki67 antigen is strictly associated with the cell cycle and confined to the nucleus, suggesting an important role in the maintenance and/or regulation of the cell division cycle.

Disclaimer
Ki67 Antigen is recommended for the detection of specific antigens of interest in normal and neoplastic tissues, as an adjunct to conventional histopathology using non-immunologic histochemical stains.



Specification


CODE

 WORKING  SOLUTION

CKM-0032

SPECIFICATION

1ml

3ml

6ml

More Info

Clone: C3G4

Source:Mouse

Localization:Nucleus

Pretreatment: Thermal remediation

Applicable tissue :Paraffin section

Reference:

1. Key G, et al. New Ki-67-equivalent murine monoclonal antibodies (MIB 1-3) generated against bacterially expressed parts of the Ki-67 cDNA containing three 62 base pair repetitive elements encoding for the Ki-67 epitope. Lab Invest. 1993 Jun;68 (6):629-36.
2. Jansen RL, et al. MIB-1 labelling index is an independent prognostic marker in primary breast cancer. Br J Cancer. 1998 Aug; 78(4):460-5.
3. Goodson WH 3rd, et al. The functional relationship between in vivo bromodeoxyuridine labeling index and Ki-67 proliferation index in human breast cancer. Breast Cancer Res Treat. 1998 May; 49(2):155-64.
4. Center for Disease Control Manual. Guide: Safety Management, NO. CDC-22, Atlanta, GA. April 30, 1976 “Decontamination of Laboratory Sink Drains to Remove Azide Salts.”
5. Clinical and Laboratory Standards Institute (CLSI). Protection of Laboratory Workers from Occupationally Acquired Infections; Approved Guideline-Fourth Edition CLSI document M29-A4 Wayne, PA 2014.

Related Product




Celnovte의 모든 제품을 만나 보세요!


IMMUNOHISTOCHEMISTRY

PRIMARY ANTIBODY

MICROSTACKER™ DETECTION SYSTEMS

MULTIPLEX IHC

FLUPRESCENCE MULTIPLEX IHC

FAST FROZEN IHC

MMR

ANCILLARIES


INSTRUMENT

IHC STAINER

CYTOLOGY STAINER

H&E STAINER

SPECIAL STAINER

ISH PROCESSOR

NUCLEIC ACID EXTRACTOR


MOLECULAR

CISH

SUPER-ISH™

FISH

CONSUMABLES


HISTOLOGY

H&E STAINS

SPECIAL STAINS


CYTOLOGY

IMMUNOCYTOCHEMISTRY

PAPANICOLAOU STAINS

p16/Ki-67

NON GYNECOLOGICAL


DIGITAL PATHOLOGY

DIGITAL SCANNER



Hytest - Official Distributor in South Korea "Morebio" 한국 공식 대리점 "모아바이오"