본문 바로가기 주메뉴 바로가기

제품소개

제품상세페이지

Minerva Biolabs

[Minerva Biolabs] Venor®GeM Advance

Cat-No. 11-7024
11-7024 / size: 25 reactions
11-7048 / size: 48 reactions
11-7096 / size: 96 reactions
11-7240 / size: 240 reactions



Minerva Biolabs는 세포배양 및 바이오의약품에서의 mycoplasma, bacteria, virus를 검출/오염방지/제거 등을

컨트롤할 수 있는 고품질의 다양한 키트와 제품을 제공하는 독일 소재의 제조사입니다. 



제품 설명


Venor®GeM Advance




제품 번호


11-7024 / size: 25 reactions

11-7048 / size: 48 reactions

11-7096 / size: 96 reactions

11-7240 / size: 240 reactions




제품 특징


Venor®GeM Advance is a kit for direct detection of mycoplasma contaminations in cell cultures, cell culture media, and other biological matrices by conventional PCR. Designed to reduce the total assay time and the pipetting steps, the kit contains PCR strips of tubes, each pre-dispensed with all reagents necessary for each PCR reaction, including the polymerase. For additional convenience, the gel loading buffer and dye are already included in the reaction buffer. After PCR, the products can be loaded directly on an agarose gel.

Type of PCR

For conventional, endpoint PCR with gel electrophoresis

Recommended Use

Applicable in research and industry for direct testing of cell cultures and biologicals. Intended for research use only. Not recommended for clinical diagnostics or testing of human samples.

Kit Components

Pre-dispensed and lyophilized Primer sets/ Nucleotides / Polymerase and Internal Control DNA, in 0.2 ml PCR reaction tubes
Rehydration buffer including gel loading buffer and running dye
Lyophilized Positive Control DNA pre-dispensed in 0.2 ml PCR reaction tubes

Package Sizes

  • Cat. No. 11-702424 Reactions
  • Cat. No. 11-704848 Reactions
  • Cat. No. 11-709696 Reactions
  • Cat. No. 11-7240240 Reactions

Result Evaluation

Gel electrophoresis at endpoint of PCR

Required Consumables

Agarose and DNA-specific dye for gel staining

Required Lab Devices

PCR cycler for conventional PCR
Agarose gel electrophoresis and gel documentation system
Pipetting equipment
Tube centrifuge

Shelf Life and Storage

Store the unopened components at +2 °C to +8 °C until the expiry date indicated on the label.
At the time of the experiments, the rehydrated reagents should be used within 1 hour.

EP 2.6.7 compliance

No

Fig. Amplified PCR products are visualized by standard gel electrophoresis.

Minerva Biolabs offers a free sample of this product for testing:




Minerva Biolabs의 모든 제품을 만나보세요!


Cell Culture Contamination Control

DNA / RNA Extraction

PCR Reagents & Enzymes

Pharma / ATMP

Decontamination Reagents for PCR Labs

Water Contamination Testing

Proficiency Testing Program 2024

Contract Manufacturing



Minerva Biolabs - Exclusive Distributor in South Korea "Morebio" 한국 독점 대리점 "모아바이오"