본문 바로가기 주메뉴 바로가기

제품소개

제품상세페이지

Biotechrabbit

[Biotechrabbit] 2X YourTaq™ Hot-Start PCR Master Mix

Cat-No. BR0202201


Biotechrabbit은 바이오의약품 및 생명과학 연구를 위한 고급 실험 재료와 서비스를 제공하는 회사입니다.




제품 설명


2X YourTaq™ Hot-Start PCR Master Mix




제품 번호


BR0202201



제품 특징


Features

  • Exceptionally pure YourTaq Hot Start DNA Polymerase
  • Optimized Master Mix for increased yield of amplification
  • Resistant to PCR inhibitor carry-over
  • Excellent PCR specificity and sensitivity for a broad range of amplicons

Applications

  • Routine and demanding PCR amplification up to 3 kb
  • Suitable for amplification of low target copy number
  • TA cloning


Description


biotechrabbit™ YourTaq Hot Start PCR Master Mix is optimized for high yield of amplification of 0.1–3 kb DNA targets, even from low copy number. The mix shows excellent PCR specificity and sensitivity for a broad range of amplicons. YourTaq Hot Start PCR Master Mix is resistant to PCR inhibitors, such as blood (up to 20%), Ethanol or humic acid enabling PCR amplification from DNA templates with carry-over of PCR-inhibitors.

The 2X YourTaq Hot Start PCR Master Mix contains pure biotechrabbit YourTaq Hot Start DNA Polymerase, extremely high-quality dNTPs and optimized PCR buffer; thus, only template, PCR primers and PCR-grade water are added. In addition, the mix is suitable for amplification of GC-rich templates (up to 70%) pairing with 5X PCR Enhancer (BR1900201).

Info: Recommended annealing temperature is 2°C above primer Tm (use gradient PCR to optimize the annealing temperature).


Other Information


Component

Composition

YourTaq Hot Start PCR Mix

Optimized 2X YourTaq Hot Start PCR Mix

 

STORAGE

-30°C to -10°C (until expiry date – see product label)

 

Quality Control
Functional assay

Human genomic DNA was amplified using the PCR Master Mix and specific primers to produce a distinct band.


Protocols

Prevention of PCR contamination

When assembling the amplification reactions, care should be taken to eliminate the possibility of contamination with undesired DNA.

  • Use separate clean areas for preparation of samples and reaction mixtures and for cycling.
  • Wear fresh gloves. Use sterile tubes and pipette tips with aerosol filters for PCR setup.
  • Use only water and reagents that are free of DNA and nucleases.
  • With every PCR setup, perform a contamination control reaction that does not include template DNA.
Standard PCR setup

The standard PCR protocol using biotechrabbit reaction buffer provides excellent results for most applications. Optimization might be necessary for certain conditions, such as the amplification of long targets, high GC or AT content, strong template secondary structures or insufficient template purity. In such cases, optimization of template purification (see biotechrabbit nucleic acid purification kits), primer design and annealing temperature is recommended.

The best conditions for each primer-template can be optimized with the following:

  • Choosing the optimal quantities of template and primers
  • Using a PCR Enhancer (i.e. BR1900201) for low amounts of template, impure or GC-rich templates
  • Optimizing cycling conditions
Basic Protocol
  • The Master Mix is designed to be used without any optimization as it has all necessary reaction components in optimal amounts for successful PCR.
  • Optionally, use the supplied 5X PCR Enhancer to increase the yield and to lower the background in more complicated PCR reactions (low amounts of template, impure or GC-rich template).
  • Thaw on ice and mix all reagents well.
  • Keep all reagents and reactions on ice.
  • Pipet the master mix into thin-walled 0.2 ml PCR tubes.
  • Add template and primers separately if they are not used in all reactions.

Component

Volume

Final concentration

2X YourTaq Hot Start PCR Mix

25 µl

5X PCR Enhancer (optional - BR1900201)

10 µl

Forward primer

Variable

0.2–1 µM

Reverse primer

Variable

0.2–1 µM

Template DNA

Variable

10 pg–1 μg

 

Use 0.01–1 ng for plasmid or phage DNA and 0.05–1 μg for genomic DNA

Nuclease free water

Variable

 

Total volume

50 µl

 

  • For total reaction volumes other than 50 µl, scale reagents proportionally.
  • Mix and centrifuge briefly to collect the liquid in the bottom of the tube.
  • Place in the PCR cycler.
Cycling Program

Step

Temperature

Time

Cycles

Initial activation

95°C

2 min

1

Denaturation

95°C

30 s

25–35

Annealing*

(55-68°C)

15–30 s

25–35

 

*Recommended annealing temperature is 2°C above Tm of primers.
Use gradient PCR to optimize the annealing temperature

Extension

72°C

30–60 s/kb

25–35

Final extension

72°C

5 min

1

 

To extend all incomplete PCR products

Storage in the cycler

4°C

Indefinitely

1

  • Add loading dye solution (see 6X DNA Loading Dye, cat. no. BR0800301) to the reactions to analyze PCR products on a gel or store them at −20°C.




Biotechrabbit에서 다양한 제품을 찾아보세요! 




Biotechrabbit - Official Distributor in South Korea "Morebio" 한국 공식 대리점 "모아바이오"