본문 바로가기 주메뉴 바로가기

제품소개

제품상세페이지

Minerva Biolabs

[Minerva Biolabs] Venor®GeM qEP

Cat-No. 11-9025



Minerva Biolabs는 세포배양 및 바이오의약품에서의 mycoplasma, bacteria, virus를 검출/오염방지/제거 등을

컨트롤할 수 있는 고품질의 다양한 키트와 제품을 제공하는 독일 소재의 제조사입니다. 



제품 설명


Venor®GeM qEP




제품 번호


11-9025




제품 특징


Venor®GeM qEP utilises quantitative, real-time PCR (qPCR) for fast (ca. 3 h) and reliable screening of cell culture supernatants for mycoplasma contaminations. The kit can be used in combination with any type of real-time PCR cycler able to detect the fluorescence dyes FAM™ and HEX™.
All Mollicutes (Mycoplasma, Acholeplasma, Spiroplasma) species so far described as contaminants of cell cultures and media components are specifically detected by amplifying a highly conserved rRNA operon, or more specifically, the 16S rRNA coding region in the mycoplasma genome. The mycoplasma-specific amplification is detected at 520 nm (FAM™ channel). False negative results due to PCR inhibitors or improper DNA extraction can be ruled out by using the provided internal amplification control, which is detected at 560 nm (HEX™ channel).

Type of PCR

TaqMan® based qPCR Assay with FAM™ and HEX™ labeled probes

Recommended Use

Applicable in research and industry for the direct detection of Mollicutes (Mycoplasma, Acholeplasma, Spiroplasma) contaminations in cell cultures and biopharmaceuticals. For testing according to EP 2.6.7, USP <1071> and JP G3.

Kit Components

Lyophilized Mix: Primer sets / Nucleotides/ Probes / Polymerase in aliquots of 25 reactions each
Rehydration Buffer
Lyophilized Internal Control DNA
Lyophilized Positive Control
PCR Grade Water

Package Sizes

  • Cat. No. 11-902525 Reactions
  • Cat. No. 11-9100100 Reactions
  • Cat. No. 11-9250250 Reactions

Result Evaluation

Cycler-based, real-time PCR

Required Consumables

PCR reaction tubes
Optional for process validation and EP 2.6.7 / JP G3 compliant testing:
Internal Control DNA Extra (4 vials for 300 µl each of internal amplification control; Cat. No. 11-9905)
10CFU™ Sensitivity Standards available for all EP 2.6.7 / JP G3 listed Mycoplasma species

Required Lab Devices

qPCR cycler with FAM™ and HEX™ filter
Pipetting equipment
Benchtop centrifuge for 1.5 ml reaction tubes

Shelf Life and Storage

Store the unopened components at +2 °C to +8 °C until the expiry date indicated on the label. Once rehydrated, the components must be stored at ≤ -18 °C.

EP 2.6.7 / USP <1071> / JP G3 Compliance

Yes.

Please note that validation data are provided for information purpose only. EP 2.6.7 clearly states “Where commercial kits are used …, documented validation points already covered by the kit manufacturer can replace validation by the user. Nevertheless, the performance of the kit with respect to its intended use has to be demonstrated by the user (e.g. detection limit, robustness, cross-detection of other classes of bacteria.”. Please feel free to contact us if you need further assistance.

Minerva Biolabs offers a free sample of this product for testing:




Minerva Biolabs의 모든 제품을 만나보세요!


Cell Culture Contamination Control

DNA / RNA Extraction

PCR Reagents & Enzymes

Pharma / ATMP

Decontamination Reagents for PCR Labs

Water Contamination Testing

Proficiency Testing Program 2024

Contract Manufacturing



Minerva Biolabs - Exclusive Distributor in South Korea "Morebio" 한국 독점 대리점 "모아바이오"