본문 바로가기 주메뉴 바로가기

제품소개

제품상세페이지

Minerva Biolabs

[Minerva Biolabs] PCR Cycler Check™

Cat-No. 57-2102 / 57-2103
57-2102 / size: PCR Cycler Check™ Advance 6 strips, 8 vials each
57-2103 / size: PCR Cycler Check™ OneStep 100 reactions



Minerva Biolabs는 세포배양 및 바이오의약품에서의 mycoplasma, bacteria, virus를 검출/오염방지/제거 등을

컨트롤할 수 있는 고품질의 다양한 키트와 제품을 제공하는 독일 소재의 제조사입니다. 




제품 설명


PCR Cycler Check™




제품 번호


57-2102 / size: PCR Cycler Check™ Advance 6 strips, 8 vials each

57-2103 / size: PCR Cycler Check™ OneStep 100 reactions




제품 특징


Validation tool for conventional PCR cyclers according to legal requirements (e.g. ISO 17025, EN 45001, ISO 13485, ISO/TS 20836:2007, GLP, GMP, IQ/OQ/PQ, and others).

False negative PCR results are highly critical and might be due to a defective PCR cycler. Verification of the correct temperature control of the equipment in-use is generally a strenuous task. Furthermore, compliance of PCR cyclers with quality management systems is not easy to achieve.
The PCR Cycler Check™ Kits provide temperature sensitive PCR reactions to monitor an upper and lower temperature range in one run. The primer/ probe sequences were designed to be extremely sensitive to fluctuations in temperature and homogeneity, precision of the temperature control and timing.
Amplification will be altered when temperature deviates by more than 2 °C from the set value. Cycler performance is tested with typical PCR settings to reflect most common applications. As an additional indicator for accurate temperature control of the cycler, the included pre-adjusted target concentrations are only amplified by highly efficient PCR reactions.

Cycler Types

Conventional thermocyclers for endpoint PCR

Benefits

  • No extra equipment, instrument or software needed.
  • Includes all you need: Lyophilized primers, polymerase, nucleotides, rehydration buffer, gel loading buffer with front marker, and marker.

Recommended Use

Applicable to any block PCR cycler in research or industrial quality control to test the legal requirements for testing the reliability of instruments used for analysis (ISO 17025, EN 45001, ISO 13485, GLP, GMP).

Kit Components

Lyophilized primer sets, polymerase and nucleotides
Rehydration buffer
Size marker for optimized gel evaluation
Gel loading buffer with front marker (only for Cat. No. 57-2103)

Package Sizes

  • Cat. No. 57-2102PCR Cycler Check™ Advance 6 strips, 8 vials each
  • Cat. No. 57-2103PCR Cycler Check™ OneStep 100 reactions

Result Evaluation

Gel electrophoresis for endpoint PCR

Required Consumables

Reagents for agarose gel electrophoresis
For Cat. No. 57-2103 only: PCR reaction tubes

Required Lab Devices

PCR cycler
Microcentrifuge
Pipettes
Agarose gel electrophoresis and documentation system

Shelf Life and Storage

Store the unopened components at +2 °C to +8 °C until the expiry date indicated on the label. All the reagents must be used directly after rehydration. For Cat. No. 57-2103: the convenient format of the Validation Reactions in single-use aliquots (1 validation assay per vial) prevents repeated freeze-thawing and waste of valuable reagents.

Minerva Biolabs offers a free sample of this product for testing:




Minerva Biolabs의 모든 제품을 만나보세요!


Cell Culture Contamination Control

DNA / RNA Extraction

PCR Reagents & Enzymes

Pharma / ATMP

Decontamination Reagents for PCR Labs

Water Contamination Testing

Proficiency Testing Program 2024

Contract Manufacturing



Minerva Biolabs - Exclusive Distributor in South Korea "Morebio" 한국 독점 대리점 "모아바이오"