[YEASEN] Annexin V- YSFluorTM 488/PI Apoptosis Detection Kit

Cat-No. 40305ES

YEASEN은 생명과학 연구 및 진단을 위한 고품질의 연구용 시약과 기기를 제공하는 글로벌 바이오 기업입니다.




제품 설명


Annexin V- YSFluorTM 488/PI Apoptosis Detection Kit




제품 번호


40305ES20 / size: 20T

40305ES50 / size: 50T

40305ES60 / size: 100T




제품 설명


Product Information

Product name

Cat#

Specification

Annexin V- YSFluorTM 488/PI Apoptosis Detection Kit  

 

40305ES20

20 T

 

40305ES50

50 T

 

40305ES60

100 T


Product description

The Annexin V-YSFluorTM 488/PI Apoptosis Detection Kit used YSFluorTM 488-labeled Annexin V as a probe to detect early Apoptosis, which could be detected by flow cytometry or other fluorescence Detection devices.

The detection principle is as follows: in normal living cells, phosphotidylserine (PS) is located in the inner side of the cell membrane, but in early apoptotic cells, PS flips from the inner side of the cell membrane to the surface of the cell membrane, and is exposed to the extracellular environment. Annexin-V is a Ca2+ -dependent phospholipid-binding protein with molecular weight of 35 to 36KD, which binds with high affinity to PS and binds to the cell membrane of early apoptotic cells through phosphatidylserine exposed on the outside of the cell.

In addition, Propidium Iodide (PI) is provided to distinguish surviving early cells from necrotic or late apoptotic cells. PI is a nucleic acid dye, which can not pass through the intact cell membrane of normal cells or early apoptotic cells, but can pass through the cell membrane of late apoptotic and necrotic cells and make the nucleus red. Thus, when Annexin V was combined with PI, PI was excluded from living cells (Annexin V-/PI-) and early apoptotic cells (Annexin V+/PI-). In contrast, late apoptotic and necrotic cells were double positive for YSFluorTM 488 and PI (Annexin V+/PI+).


Components

Component

 

40305ES2020T

40305ES5050T

40305ES60100T

40305-A

Annexin V-YSFluorTM 488

100 μL

250 μL

500 μL

40305-B

PI Staining Solution (20 μg/mL)

200 μL

500 μL

1.0 mL

40305-C

4×Binding Buffer

10 mL

25 mL

50 mL


Storage

The components are shipped with ice pack and can be stored at -20°C for 1 year.


Cautions

  1. Since apoptosis is a rapid process, it is recommended that samples be analyzed within 1 hour after staining.
  2. For adherent cells, digestion is a critical step. Do not use EDTA in the digestive solution as EDTA can affect the binding of Annexin V to PS.
  3. If the sample is from blood, be sure to remove platelets from the blood. Because platelets contain PS, which can bind to Annexin V, interfering with the results. A buffering agent containing EDTA can be used and the platelets washed away by centrifugation at 200 g.
  4. Please centrifuge the reagent briefly before opening the cover, and throw the liquid on the inner wall of the cover to the bottom of the tube to avoid liquid sprinkling when opening the cover.
  5. Annexin V-YSFluorTM 488 and PI are photosensitive substances and should be kept away from light when handling.
  6. For research use only! 


Instructions

    1. Sample dyeing
  1. a) suspension cell:  Cells were collected by centrifugation at 300 g for 5 min at 4 ° C.

         b) adherent cell: After digestion with trypsin without EDTA, cells were harvested by centrifugation at 300 g for 5 min at 4 ° C. Trypsin digestion time should not be too long to prevent false positives.

       2. The cells were washed twice with PBS precooled at 4 ° C, each time using 300g, and centrifuged at 4 ° C for 5 min.

       3. Cells were resuspended by adding 250 μL 1×Binding Buffer, and the concentration was adjusted to 1×106/mL.

       4. 100 μL of cell suspension was added into a 5mL flow cytometry tube, 5μL Annexin V-YSFluorTM 488 and 10 μL PI were added, and gently mixed.

       5. The reaction was kept away from light and kept at room temperature for 15 min.

       6. 400 μL of 1×Binding Buffer was added, mixed, and the samples were detected by flow cytometry within 1 hour.

NotesTo avoid cell loss during cell washing, a small Tip can be used to aspirate fluid.

    1. Flow cytometry analysis

YSFluorTM 488 has a maximum excitation wavelength of 488 nm and a maximum emission wavelength of 519 nm;The maximum excitation wavelength of PI-DNA complex was 535 nm, and the maximum emission wavelength was 615 nm. CellQuest and other software were used to analyze and draw two-color dot plot with YSFluorTM 488 as abscissa and PI as ordinate. Collect 10,000 events per sample.

    1. Fluorescence microscopy analysis
  1. Drop a drop of the cell suspension double-stained with Annexin V-FITC/PI onto the slide and cover the cells with a cover slip.
  2. It was observed under a fluorescence microscope with a two-color filter. Annexin V-FITC fluorescence signal was green, and PI fluorescence signal was red.




YEASEN의 모든 제품을 만나 보세요!


Biopharma

mRNA enzyme

Nucleotides

Viral Vector Manufacturing

Quality Analysis Kit


NGS Library Preparation

Adapter

DNA Library Preparation

RNA Library Preparation

NGS Module

NGS enzyme

Magnetic Bead

Library Quantitation


Molecular Diagnostics

Glycerol-free Enzyme

RT-qPCR Enzyme

RT-LAMP Enzyme

dNTPs

IVD Kit


Life Science Reagents

Hot Products

Molecular Biology

Cell Culture & Analysis

Protein Research

Animal Model

Others


YEASEN - Official Distributor in South Korea "Morebio" 한국 공식 대리점 "모아바이오"