본문 바로가기 주메뉴 바로가기

제품소개

제품상세페이지

YEASEN

[YEASEN] Hieff UNICON™ ColorGPS qPCR Master Mix (No Rox)

Cat-No. 11188ES

YEASEN은 생명과학 연구 및 진단을 위한 고품질의 연구용 시약과 기기를 제공하는 글로벌 바이오 기업입니다.





제품 설명


Hieff UNICON™ ColorGPS qPCR Master Mix (No Rox)




제품 번호


11188ES




제품 설명


Description

Hieff UNICON™ ColorGPS qPCR Master Mix (No Rox) is a pre-solution for 2×real-time quantitative PCR amplification, featuring high fluorescence intensity, high sensitivity and specificity, and high amplification yield. The core component, Hieff UNICON™ Taq DNA Polymerase, is hot-started by antibody method, which can effectively inhibit non-specific amplification caused by primer annealing during sample preparation. At the same time, the formula adds factors to enhance the amplification efficiency of the PCR reaction and facilitators to equalize the amplification of genes with different GC contents (30~70%), so that the quantitative PCR can obtain a good linear relationship in a wide range of quantitative regions. The product utilizes the mixed color change reaction of different dyes to monitor the pipetting operation, which effectively reduces the occurrence of pipetting errors.


Features

  • Pipetting Tracking: Reduce the Risk of Missed/Addition Errors

    Excellent Amplification: Good linearity across a wide linear range

    High Precision: Can accurately distinguish templates with a 2-fold concentration difference

    Good Repeatability: Small inter-well variability in replicate wells, resulting in better repeatability

    Stable and Reliable: The reaction system can be stored at room temperature for 24 hours, and the product remains unaffected after 20 freeze-thaw cycles


Specifications

Concentration

2 ×(qPCR Mix)

Detection method

Dye method

PCR method

qPCR

Polymerase

Taq DNA Polymerase

Type of sample

DNA

Application equipment

Bio-Rad CFX96, CFX384, iCycler iQ, iQ5, MyiQ; MiniOpticon, Opticon, Opticon 2, Chromo4; Cepheid SmartCycler; Eppendorf Mastercycler ep realplex, realplex 2 s; Illumina Eco qPCR; Qiagen/Corbett Rotor-Gene Q, Rotor-Gene 3000, Rotor-Gene 6000;Roche Applied Science LightCycler 480; Thermo Scientific PikoReal Cycler and other fluorescence quantitative PCR instruments that do not require the addition of ROX Reference Dye

Product Type

Premix for real-time fluorescence quantitative PCR

Apply to (application)

Gene Expression


Components

Components No.

Name

11188ES03

11188ES08

11188ES60

11188-A

Hieff UNICON ColorGPS qPCR  Master Mix (No Rox)

1 mL

5×1 mL

100×1 mL

11188-B

10×Dilution Buffer

1 mL

1 mL

20×1 mL


Shipping and Storage

This product should be stored at -25~-15℃ for 1 years.


Application

Gene Expression Difference Analysis

Absolute Quantitative Analysis


Figures

Figure1. Reliable results can be obtained within the dynamic range.

Figure1. Reliable results can be obtained within the dynamic range.

Using 2 µL of plasmid templates with a gradient of 10^1-10^7, the related genes were amplified. Hieff UNICON ColorGPS master mix can effectively detect a template amount range of 7 orders of magnitude, achieving good linearity within a broad linear range. 

Figure2. Can accurately distinguish template concentration differences of 2-fold.

Figure2. Can accurately distinguish template concentration differences of 2-fold.

Using 2 µL of plasmid diluted in a 2-fold gradient as the template, the related genes were amplified. Hieff UNICON ColorGPS master mix can accurately resolve template concentration differences. 

Figure3. Small inter-well variability is observed, showing better repeatability.

Figure3. Small inter-well variability is observed, showing better repeatability.

Using dozens of copies of plasmid as the template, amplification was performed with different fluorescent quantitative reagents according to the procedures specified in their respective instruction manuals. The SD values indicate that, compared to other reverse transcription reagents, the new product has smaller differences between replicate wells and better repeatability. 

 

Figure4. More flexible, suitable for standard or rapid procedures.

Figure4. More flexible, suitable for standard or rapid procedures.

In the standard procedure, the denaturation time and extension time are set to 10 seconds and 30 seconds, respectively, while in the rapid procedure, the denaturation time and extension time are set to 3 seconds and 10 seconds, respectively, to detect the Ct values corresponding to 10 target genes. The results show that the Ct values obtained with the new product in both standard and rapid procedures have a strong correlation, and the new product can achieve good results using the rapid procedure. 

Figure5. After the reaction system is prepared, it can remain stable at room temperature for 24 hours.

Figure5. After the reaction system is prepared, it can remain stable at room temperature for 24 hours.

Using different genes from mouse, human 293 cells, and Arabidopsis thaliana as targets, after preparing the reaction system, it was placed in the dark at different temperatures for 24 hours before detection. Compared to immediate processing, the detection difference for different genes does not exceed 0.5 Ct, indicating that stable results can also be obtained with long-duration operations. 




YEASEN의 모든 제품을 만나 보세요!


Biopharma

mRNA enzyme

Nucleotides

Viral Vector Manufacturing

Quality Analysis Kit


NGS Library Preparation

Adapter

DNA Library Preparation

RNA Library Preparation

NGS Module

NGS enzyme

Magnetic Bead

Library Quantitation


Molecular Diagnostics

Glycerol-free Enzyme

RT-qPCR Enzyme

RT-LAMP Enzyme

dNTPs

IVD Kit


Life Science Reagents

Hot Products

Molecular Biology

Cell Culture & Analysis

Protein Research

Animal Model

Others


YEASEN - Official Distributor in South Korea "Morebio" 한국 공식 대리점 "모아바이오"